Technical parameters
| Parameter | Value |
|---|---|
| Dilution | 1:20 with water; less for heavy contamination |
| Bath temperature | approx. 40 °C |
| Removes | uncured resin, epoxy, adhesive, paint, oil, grease |
| Packaging | 5, 60, 200 and 1000 l |
| Flammability | non-flammable |
| Storage | cool, dry, out of direct sunlight |
The figures come from the product datasheet — we verify them in our own applications.
How to use
- Dilute 1:20 with water — less for heavy contamination — and heat to about 40 °C.
- Submerge the parts and add mechanical action: agitation or a brush.
- Remove and let dry.
- For mould surfaces, put the diluted solution on a cloth — same dilution, no heating.
In practice
- 400 l
- of acetone a month replaced by 5 l of concentrate diluted 1:20
- ¼
- of the workstation's former cleaning cost
Watch out for
- It will not strip fully cured laminate — clean tools before the resin cross-links.
- A bath needs more handling than acetone — two hours a month instead of one in the comparison above — and still comes out far cheaper.
- It does not replace every cleaning job — acetone stays in use for some tasks.
- On delicate surfaces the manufacturer recommends a patch test.
Packaging and accessories
- Ready-to-use 500 ml spray and cleaning wipes for quick jobs at the machine
- 100 and 400 l washing stations for continuous tool cleaning (Tools category)
Downloads
The technical and safety data sheets are being prepared for download — until then we send them promptly on request.